TRANSPORT
®
Rear Panel Pinouts
Pin
LAN
Ethernet
LAN
Token Ring
SUPV/SLIP
Terminal
SUPV/SLIP
Modem
Network
1 Data Out DCD Out DTR Out Data Out
2 Data Out CTS Out RTS Out Data Out
3 Data In Data Out Frame Gnd Frame Gnd
4 Data In Data Out Data Out
5 Data In Data In Data In
6 Data In Data Out Signal Gnd Signal Gnd
7 RTS In CTS In Data In
8 DTR In DCD In Data In
Factory defaults for all switch
settings are shown underlined
.
Rear Panel
127 Jetplex Circle
Madison, Alabama 35758
Sales and Marketing
800-926-0085
205-772-3770
info@txport.com
Returns/RMA
800-926-0085, ext. 2227
Technical Support
800-285-2755
205-772-3770
support@txport.com
Switch S1
S1-1: Antistream timer set to 30 seconds.
Dn: Disable
Up: Enable
S1-2: Activates the V.54 loop/unloop.
Dn: Enable
Up: Disable
S1-3: Activates the circuit assurance.
Dn: Disable
Up: Enable
S1-4: Establishes the loop mode.
Dn: Bidir
Up: Unidir
S1-5: Not Used
S1-6: Not Used
S1-7: Not Used
S1-8: Not Used
Switch S2
S2-1: Boot mode.
Dn - Switches
Up - Saved Configuration
S2-2: DDS mode as DDS I (56 kbps) or DDS II
(64 kbps).
Dn - 64 kbps
Up - 56 kbps
S2-5: CTS Delay.
Dn: Short
Up: Long
S2-6: RTS, CTS, DCD Handshake.
Dn: Force True
Up: Normal
S2-7: Remote/Local loops on the DTE interface.
Dn: Disable
Up: Enable
S2-8: DTE Alarm.
Dn: Disable
Up: Enable
S2-3 S2-4 Timing Source
Dn
Dn Network
Dn Up Internl
Up Dn DTEl
Up Up Not Used
Data
Port Pinouts
Common Name
V.35
34-pin
Frame Ground A
Transmit Data P, S
Receive Data R, T
Request to Send C
Clear to Send D
Data Set Ready E
Signal Ground B
Data Carrier Detect F
Receive Clock V, X
Terminal Timing U, W
Transmit Clock Y, AA
Local Loopback J
Data Term Ready H
Remote Loopback BB
SUPVSLIPLAN
NET
V.35
115 VAC
60 HZ
S2 S1
DTE
NET
Line Loop
DTE
NET
Data Loop
V.54 Loop
DTE
NET
Local Loop
Loops