Switch S2
S2-1 through S1-5:Determine the data
port bit rate. Refer to the Data Port Bit
Rates chart for configuration settings.
S2-6: Sets the channel assignment mode.
Dn: Contiguous
Up: Alternate
S2-7: Sets the data port rate multiplier.
Dn: N x 64 k
Up: N x 56 k
S2-8: Sets the power-up mode.
Dn: Switches
Up: RAM
S2-9 S2-10 SUPV Port Rate
Up Up 1.2 kbps
Dn Up 2.4 kbps
Dn
Dn 9.6 kbps
Up Dn 19.2 kbps
Rear Panel Pinouts
Pin
SUPV
Terminal
SUPV
Modem
Network
1 DCD Out DTR Out Data In
2 CTS Out RTS Out Data In
3 Frame Gnd Frame Gnd Not Used
4 Data Out Data Out Data Out
5 Data In Data In Data Out
6 Signal Gnd Signal Gnd Not Used
7 RTS In CTS In Chassis Gnd
8 DTR In DCD In Chassis Gnd
Factory defaults for all switch settings are
shown underlined
.
Switch S2-9 and S2-10 must be set before
powering the unit.
Rear Panel
TxPORT
127 Jetplex Circle
Madison, Alabama 35758
Customer Service
800-926-0085, ext. 2227
info@txport.com
Switch S1
S1-1: Set the network line framing.
Dn - ESF
Up - D4
S1-2: Sets the network line coding.
Dn - B8ZS
Up - AMI
S1-7: Test button loop code.
Dn: LLB code
Up: V.54 code
S1-8: Test button operational mode.
Dn: BERT
Up: Clear loop
S1-3 S1-4 Network LBO
Dn
Dn 0 dB
Up Dn -7.5 dB
Dn Up -15.0 dB
Up Up -22.5 dB
S1-5 S1-6 Timing Source
Dn
Dn Network
Up Dn Internal
Dn Up Port 1 EXC
Up Up N/A
Data Port Bit Rates
# of
DSOs
S2-7
Up Dn
S2-1 S2-2 S2-3 S2-4 S2-5
Disable
Disable Dn Dn Dn Dn Dn
1 56 kb/s 64 kb/s Up Dn Dn Dn Dn
2 112 128 Dn Up Dn Dn Dn
3 168 192 Up Up Dn Dn Dn
4 224 256 Dn Dn Up Dn Dn
5 280 320 Up Dn Up Dn Dn
6 336 384 Dn Up Up Dn Dn
7 392 448 Up Up Up Dn Dn
8 448 512 Dn Dn Dn Up Dn
9 504 576 Up Dn Dn Up Dn
10 560 640 Dn Up Dn Up Dn
11 616 704 Up Up Dn Up Dn
12 672 768 Dn Dn Up Up Dn
13 728 832 Up Dn Up Up Dn
14 784 896 Dn Up Up Up Dn
15 840 960 Up Up Up Up Dn
16 896 1024 Dn Dn Dn Dn Up
17 952 1088 Up Dn Dn Dn Up
18 1008 1152 Dn Up Dn Dn Up
19 1064 1216 Up Up Dn Dn Up
20 1120 1280 Dn Dn Up Dn Up
21 1176 1344 Up Dn Up Dn Up
22 1232 1408 Dn Up Up Dn Up
23 1288 1472 Up Up Up Dn Up
24 1344 1536 Dn Dn Dn Up Up
Data Port Pinouts
Common Name
DB25
25-pin
V.35
34-pin
Frame Ground 1 A
Signal Ground 7 B
Transmit Data 2, 14 P, S
Receive Data 3, 16 R, T
Request to Send 4, 19 C
Clear to Send 5, 13 D
Data Set Ready 6, 22 E
Data Term Ready 20, 23 H
Data Carrier Detect 8, 10 F
Transmit Clock 15, 12 Y, AA
Receive Clock 17, 9 V, X
Terminal Timing 24, 11 U, W
SUPV
NET
DATA PORT 1
115 VAC
60 HZ
S1
S2
Technical Support
(8 a.m. to 5 p.m. Central Time)
Toll Free:888-4TxPORT
800-285-2755 (and af-
ter-hours emergencies)
Locally: 205-772-3770
e-mail: support@txport.com