TRANSPORT
®
76543219765432 8
S1 S2
V. 35
1
93-130
VAC
1 - 5 DSOs Assigned: These five positions select the bit rate and the number of DSOs assigned to the
channel (refer to the table below).
6 Rate Multiplier: Sets the multiplier for the input timing (refer to the table below). The unit oper-
ates at any data rate that is a multiple of 56 or 64 kbps.
7 Channel Assignment: The Contiguous mode assigns the channels as a block beginning at DS0
channel 1. If ‘Alternate’ is selected, channel assignments are made with an idle channel following
each data channel.
8 Control Lines: ‘On’ permanently sets the CTS, DSR, and CD leads to ON. With ‘Follow’, the
DSR lead follows T1 sync, the CTS lead follows RTS, and the CD lead follows the density status
of the incoming T1 signal (175 zeros = CD OFF). The TM line goes high when the unit is in a
local or remote test mode.
9 Data Invert: Determines whether the data bits are inverted.
NOTE: The ‘A’ position is the factory default for
all switch settings. If a particular user configuration
requires that a switch be placed in the ‘B’ direction,
then mark this sheet for future reference.
Circuit Pin # Signal Name DCE
101 A Frame Ground Ground
102 B Signal Ground Ground
103 P/S Transmit Data In
104 R/T Receive Data Out
105 C Request To Send In
106 D Clear To Send Out
107 E Data Set Ready Out
109 F Data Carrier Detect Out
113 U/W External Transmit Clock In
114 Y/AA Transmit Clock Out
115 V/X Receive Clock Out
142 K Test Mode Out
V.35 Interface
DSO S1-1 S1-2 S1-3 S1-4 S1-5 S1-6 (A) S1-6 (B)
1 B B B B B 56 kb 64 kb
2 B A B B B 112 128
3 A A B B B 168 192
4 B B A B B 224 256
5 A B A B B 280 320
6 B A A B B 336 384
7 A A A B B 392 448
8 B B B A B 448 512
9 A B B A B 504 576
10 B A B A B 560 640
11 A A B A B 616 704
12 B B A A B 672 768
13 A B A A B 728 832
14 B A A A B 784 896
15 A A A A B 840 960
16 B B B B A 896 1024
17 A B B B A 952 1088
18 B A B B A 1008 1152
19 A A B B A 1064 1216
20 B B A B A 1120 1280
21 A B A B A 1176 1344
22 B A A B A 1232 1408
23 A A A B A 1288 1472
24 A
A A A A 1344 1536
DTE
NET
Local Loopback
DTE
NET
Remote Channel Loop (V.54)
DTE
NET
* Signal regeneration only
*
CSU Line Loop (Inband or LLB)
Loops
1 Data In (R1)
2 Data In (T1)
3/6 Not Used
4 Data Out (R)
5 Data Out (T)
7/8 Chassis Gnd
Network Pinout
1 - 2 Timing Source: This position selects the source of unit clocking (refer to the Switch S2 table).
3 Not used.
4 Network Framing: This position selects the network framing to either ESF
or D4.
5 Network Coding: This position selects the network line code format to either AMI
or B8ZS.
6 - 7 Network LBO: This position selects the network LBO (line build out) signal level of the data
transmitted towards the T1 facility (refer to the Switch S2 table).
Switch S1 Description
Switch S2 Description
65431 7 982
56 kbps
Contiguous
Control
Data Invert
64 kbps
Alternate
Control
Data Invert
Follow
On
No
Yes
Switch S1
DSOs Assigned
(see table at bottom)
81
NET
A
B
A
B
127 Jetplex Circle
Madison, Alabama 35758
Sales and Marketing
800-926-0085
205-772-3770
info@txport.com
RMA/ Returns
800-926-0085, ext. 2282
Technical Support
800-285-2755
205-772-3770
support@txport.com
Not
ESF
AMI
Not
D4
B8ZS
54321 6 7
B
A
A
A
B
A
Network clock (looped)
Internal clock (master)
CPE clock (external)
Timing
Source
Network
LBO
B B
B
A
A
A
B
A
0
-22.5
-7.5
-15
Switch S2
A
B
Used
Used
B B Not Valid