4-38 WANsuite 5370
Remote Unit
If the remote unit is a Verilink unit with FrameStart technology, and
FrameStart Auto Discovery is enabled, this field displays the first three digits
of the unit ID configured on the remote end of this DLCI.
Values: 000999
Default: 000
Remote IP Address
Displays the IP address of the remote Verilink unit with FrameStart
technology if FrameStart Auto Discovery is enabled.
Remote IP Address
Displays the IP address of the unit configured on the remote end of this
DLCI.
Round Trip Delay
Specifies the frame size (in bytes) of packets making the round trip.
Round Trip Rate
Specifies the rate (in seconds) at which Round Trip Delay packets are sent.
DLCI Status Table
The bottom portion of the screen shows a table detailing the actual status of this
DLCI and alarm threshold information as follows:
Status
If this DLCI is up, the status will be “Active”; otherwise, the status will be
“Inactive.”
Values: Active, Inactive
Default: Inactive
Receiving FECN/
BECN
When a frame is received with congestion bit set, this parameter is set to
“Yes.” It is set back to “No” when a frame is received without congestion bit
set.
Values: Yes, No
Default: No
CIR Threshold
Sets the Tx over CIR alarm threshold. This threshold is the number of bits per
second in excess of CIR during a 15-minute interval. Setting this field to “0”
(zero) disables the alarm.
CIR Alarm
Reports if the Tx over CIR threshold has been exceeded.
Bits Over Be Threshold
Sets the Tx over Be alarm threshold. This threshold is the number of bits per
second in excess of CIR + Be during a 15-minute interval. Setting this field to
“0” (zero) disables the alarm.
Bits Over Be Alarm
Reports if the Tx over Be threshold has been exceeded.
Congestion Threshold
Sets the Rx Congestion alarm threshold. This threshold is the number of
frames received with BECN/FECN. Setting this field to “0” (zero) disables
the alarm.
Congestion Alarm
Reports if the Rx Congestion threshold has been exceeded.
Vedere la pagina 153
1 2 ... 149 150 151 152 153 154 155 156 157 158 159 ... 234 235

Commenti su questo manuale

Nessun commento

Atlas Sound Micrófonos manuales de usuario

Empezando en 0-9

Haga clic en el alfabeto a continuación para desplazarse a la lista completa de modelos que comienzan con esa letra

Modelos Tipo de documento
417-8WD
Manual de usuario   Atlas Sound 417-8WD User Manual, 1 paginas
51-8
Manual de usuario   Atlas Sound 51-8 User Manual, 2 paginas
8" 2-Way Stadium Horn System AH94-8ST
Manual de usuario   Atlas Sound 8" 2-Way Stadium Horn System AH94-8ST User Manual, 4 paginas
8" 2-Way Staium Horn System AH66-8ST
Manual de usuario   Atlas Sound 8" 2-Way Staium Horn System AH66-8ST User Manual, 4 paginas
8" AH Series Stadium Horns AH99-8ST
Manual de usuario   Atlas Sound 8" AH Series Stadium Horns AH99-8ST User Manual, 4 paginas