Verilink SNMP SNMP-1
SNMP
SNMP Management
This part of the Management Section briefly describes the SNMP
(Simple Network Management Protocol) support provided by the
Verilink SCM and NCM controller modules. It contains an
explanation of the SNMP support that permits access to SCM- and
NCM-controlled nodes by the SNMP manager of your choice. You
should be familiar with SNMP and the SNMP manager you are using.
The SCC module supports SNMP for legacy products only. The
Quad/IMUX module supports SNMP as a standalone module. See
these application modules for further information.
Overview
SNMP is a network management protocol that is widely accepted for
controlling network equipment. SNMP has been implemented on
Verilink equipment to provide customers the flexibility to use the
Craft interface or an SNMP network management system. The SNMP
implementation provided by Verilink has been tested using HP
OpenView
TM
and Verilink’s SNMP management system embedded in
the Verilink Node Manager.
The SCM and NCM supports the following MIB tables:
DS1 MIB Interface
Verilink Enterprise MIB
Getting Started
This document is a reference, not a tutorial. The preliminary steps
to using SNMP with your network SNMP management system are:
1. Compile the MIBs if they have not already been prepared.
2. Perform a request for [system] MIB to confirm the connection
to the node.
3. Access the [ncm.generic] table using the path:
iso.org.dod.internet.private.enterprises.verilink.as2000.ncm_generic
4.
Go to the table
NCM
.N
ODE
C
URR
T
ABLE
and select “Active“ via the
NCM Active Node Status to activate node control.
5. Go to [ncm_generic] table
NCM
S
HELF
I
NFO
T
ABLE
and set the
ncmShelfHardware to indicate the shelf type.
Vedere la pagina 0
1 2 3 4 5 6 ... 13 14

Sommario

Pagina 1 - SNMP Management

Verilink SNMP SNMP-1 SNMPSNMP ManagementThis part of the Management Section briefly describes the SNMP (Simple Network Management Protocol) support pr

Pagina 2 - SNMP Interface Specifications

SNMP ManagementSNMP-10 Verilink SNMPTable 10 Far End Group3DS1 Fractional Group parameters are not supported in this release.dsx1FarEndIntervalUASs T

Pagina 3 - Controlled

SNMP ManagementVerilink SNMP SNMP-11Verilink Enterprise MIBVerilink supports various enterprise-specific MIBs. Specific information on the Verilink

Pagina 4 - MIB Tables

SNMP ManagementSNMP-12 Verilink SNMP•Status {manditory, not manditory}•Syntax {specifies values allowed by the object}•Description {provides explanati

Pagina 5 - DS1 MIB Interface

SNMP ManagementVerilink SNMP SNMP-13DIU1. The “run BER test” option works only for the DIU 2130 module and not for the DIU/DBU or DIU/DDS modules.2.

Pagina 6

SNMP ManagementSNMP-14 Verilink SNMP

Pagina 7

SNMP ManagementSNMP-2 Verilink SNMPYou are now ready to manage the system. To change the active node being managed by your management system, return t

Pagina 8

SNMP ManagementVerilink SNMP SNMP-3For example, you would calculate each interface’s number for a module (plug) in Shelf 2, Slot 2, as follows:Table

Pagina 9 - DS1 Far End Group

SNMP ManagementSNMP-4 Verilink SNMPIn Table 3 below, column 1 specifies the modules controlled and column 2 specifies the associated MIB tables that

Pagina 10

SNMP ManagementVerilink SNMP SNMP-5DS1 MIB InterfaceTables 4 through 10 list the various MIB-II interface parameters. The accompanying comments expla

Pagina 11 - Enterprise MIB

SNMP ManagementSNMP-6 Verilink SNMPNOTE: To determine the clock source for Verilink products, see the Verilink enterprise MIBs.Table 5 DS1 Near End G

Pagina 12 - Warnings

SNMP ManagementVerilink SNMP SNMP-7dsx1CurrentLESs The number of ES-L in the current 15-minute interval.dsx1CurrentBESs The number of Bursty Errored

Pagina 13 - Verilink SNMP SNMP-13

SNMP ManagementSNMP-8 Verilink SNMPTable 6 Near End Group 3Table 7 Near End Group 4Object-Type Parametersdsx1IntervalIndex A number calculated with

Pagina 14 - SNMP-14 Verilink SNMP

SNMP ManagementVerilink SNMP SNMP-9DS1 Far End GroupThe DS1 Far End group only applies to the SCC controller module.Table 8 Far End Group1Table 9 F

Commenti su questo manuale

Nessun commento